Sysmex Xn 1000 User Manual Pdf

XN-1000 * 100 samples/h * Sampler capacity 5 racks * Choose diagnostic APPs as needed * Short turnaround times * Networking and remote services capabilities XN-1000 - introducing Sysmex´s flagship analyser This is a standalone, benchtop instrument. In its Rerun & Reflex configuration, the XN-1000 offers reproducible result quality in the shortest possible time. By automatically reanalysing samples for which results are considered unreliable, it significantly reduces manual interventions and frees up time and resources. With no compromise on turnaround time. Reagent management is simple too – if you want we can integrate your reagents in an analyser wagon. The XN-1000 can be equipped with all the available diagnostic applications. Depending on what is installed, the XN Rerun & Reflex performs a range of rule-based tests. The samples in question are fed into extended measurement automatically. Extended measurement is only performed if it adds additional diagnostic value. While the XN-1000 is a standalone system, optional software can still make it uniquely flexible. It can be networked with other XN concepts at other locations. Think of individual systems for measuring body fluids on neurology wards. Or transfusion centres. And thanks to our remote services, we can together define levels of support quality, guaranteed service response times and ensure maximum system uptime. XN-Series specifications Technology Fluorescence Flow Cytometry in all modes Aspiration volume 88µL in all modes Throughput starting from 100 samples/h Quality control XN Check and XN Check BF Parameters 28 diagnostic parameter always standard XN-CBC = always with NRBC XN-DIFF = efficiency of XE-5000 16 diagnostic parameters are optional Core models Design and specifications may be subject to change due to further product development. Sysmex Europe GmbH, Bornbarch 1, 22848 Norderstedt, Germany, Phone: +49 (40) 527 26 0, Fax: +49 (40) 527 26 100 www.sysmex-europe.com

Open the catalog to page 1

Sysmex Xn 2000 Manual Pdf

XN-1000 Pure * Highest quality, even for low sample throughputs * NRBC for every blood cell count * Up to 100 samples/h in sampler operation * Networking and remote services capabilities * Optional capability: automated measurement of reticulocytes and automated measurement of body fluids XN-1000 Pure Now laboratories with lower needs can afford XN-technology and ensure precise determination of the NRBC, even at the lowest concentrations. The XN-1000 Pure is available in the following configurations: * XN-1000 [DIFF] – for measuring the complete blood count incl. NRBC and differential blood count incl. IG * XN-1000 [RET] – for measuring the complete blood count incl. NRBC, differential blood count and reticulocytes (incl. PLT-O) Optionally, the XN-1000 Pure can be configured with the XN-BF application for measuring body fluids. XN-1000 Pure specifications Measurement principles WBC DIFF/RET: Fluorescence Flow Cytometry RBC/PLT: Hydrodynamically focussed impedance HGB: Cyanide-free SLS haemoglobin Aspiration volume 88 µL in whole blood (WB) mode and body fluid (BF) mode Throughput Up to 100 samples/hour Quality control material XN Check (three levels) and XN Check BF (two levels) Parameters XN-CBC (always with NRBC) & XN-DIFF (always with IG) Whole Blood WBC, NRBC%, NRBC#, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MicroR%, MacroR%, PDW, MPV, Sysmex Europe GmbH, Bornbarch 1, 22848 Norderstedt, Germany, Phone: +49 (40) 527 26 0, Fax: +49 (40) 527 26 100, www.sysmexeurope.com Probability and queuing theory by g.balaji pdf.

1000

Sysmex Xn 1000 User Manual Pdf Online

The Sysmex XW-100 is the first FDA-cleared, CLIA-waived CBC analyzer to provide reliable, convenient, and often, same-visit CBC results. Customers located in Canada: Product availability may be different from the U.S. Please call Sales at 1-866-779-7639 for more information.

Post navigation. Christophe MonierHello, It would be super awesome to have a modern 64-bit version of Detroy FX dfx Buffer Override for macOS. Buffer override vst download. ↓.

Sysmex Xn 1000 User Manual Pdf Download

Open the catalog to page 1
Comments are closed.